The cryogenic air separation plant, also often called the cryogenic air separation unit (ASU), is a large industrial complete set of equipment. It takes the air in the atmosphere as the raw material, through the very low temperature (cryogenic temperature) combined with the distillation process, the air is separated into oxygen, nitrogen, can also generate argon.
This set of technology is the mainstream solution for large-scale production of high-purity industrial gases, with a single set of production capacity of hundreds to thousands of tons per day. If it is a scenario with medium and small gas volume and general purity requirements, the industry is more likely to use pressure swing adsorption (PSA) or membrane separation processes.
The underlying logic of cryogenic air separation is to use the difference in the boiling point of each component in dry air at atmospheric pressure.
The whole system is placed in a cold box with high thermal insulation, and energy saving is realized by high thermal integration. Most of the cooling capacity of the device comes from the work done by the raw material air compression process, and does not require a large amount of external cold source.
The process of the cryogenic air separation plant includes compressing and purifying the ambient air, and then cooling the air to cryogenic temperature to achieve partial liquefaction. The boiling point difference of each component is used to separate the components by distillation; the whole process relies on the cold flow of the product to recover the cold energy, and the refrigeration mainly relies on air expansion to do work.
Ambient air will enter the device through high-level or special air inlet, and first pass through the filter to remove dust, solid particles and other impurities.
The filtered air enters the main air compressor (MAC), mostly using oil-free multistage centrifugal compressors. The air is pressurized to 5-10 bar, and the specific pressure value is determined by the device design and product requirements.
There is an intercooler between all stages of the compressor, which takes away a lot of heat generated by compression, condenses most of the water vapor and discharges it. The air compression link occupies most of the power consumption of the entire air separation unit, and also determines the subsequent operating pressure of the whole process.
The compressed air enters the pre-cooling unit (or cooling tower) to further cool down, and the temperature drops to 5~15 ℃. Cooling can reduce the load of the purification system and release a part of the remaining water vapor in the air.
After cooling, the high-pressure air enters the pre-purification unit (PPU), and the double bed of activated alumina and zeolite molecular sieve is filled inside. The molecular sieve bed will remove residual water, carbon dioxide, and hydrocarbons to very low levels.
Impurity removal is the key to ensure the safe operation of the equipment. If water vapor and CO₂ remain, it will freeze in the cryogenic equipment, block the pipes and flow channels, and cause the risk of downtime.
The purification system adopts the temperature swing adsorption (TSA) cycle mode. One adsorption bed removes impurities online, the other bed uses hot waste nitrogen regeneration, and the two beds work alternately to ensure continuous gas supply.
The purified high-pressure air enters the cold box. The cold box shell is filled with insulation materials such as pearlescent sand to minimize the penetration of external heat.
The air flows into the main heat exchanger (MHE), typically a brazed aluminum plate-fin multi-stream heat exchanger. The raw material air and the low-temperature product flow of the reflux are countercurrent heat exchange, and the temperature is continuously reduced.
In order to reach the cryogenic condition of -170 ℃ ~ -185 ℃, supplementary refrigerating capacity is required. Part of the air enters the turbine expander to obtain cold through external work expansion; part of the process is equipped with Joule-Thomson throttle valve to assist in cooling.
The air continues to cool, most of the medium liquefaction, forming a gas-liquid two-phase mixture. The mixture comprising oxygen-rich liquid and nitrogen-rich vapor is sent to a rectification system for separation.
Part of the liquefied air into the distillation system, modern air separation almost all of the use of high and low pressure double tower structure arranged in the cold box.
The operating pressure of the high-pressure column (HP column) is above 5-6 bar, and the preliminary separation is completed. Nitrogen with a lower boiling point forms vapor upward, and condensation at the top of the column produces reflux; the bottom of the column is enriched with oxygen-rich liquid of 35% to 40% oxygen.
The operating pressure of the low-pressure column (LP column) is about 1.1-1.5 bar, and it receives the oxygen-rich liquid sent by the high-pressure column to complete the final purification. High purity nitrogen vapor is produced at the top of the tower, and high purity liquid oxygen is collected at the bottom of the tower.
High and low pressure twin towers rely on condensing evaporators to achieve thermal coupling. Nitrogen condensation at the top of the high-pressure tower releases heat, which provides evaporation heat source for the bottom of the low-pressure tower to maximize energy utilization.
If the customer needs to recover argon, a 1 stream of gas phase material will be withdrawn from the argon enrichment zone in the middle of the low pressure column. The material is sent to an independent argon tower for further distillation and purification to produce qualified argon products.
The cryogenic products (gaseous nitrogen, liquid oxygen, optional liquid argon/gas argon) of the completed separation leave the rectification column. The airflow first returns to the main heat exchanger to be reheated to close to normal temperature, and the cold energy carried by itself is transferred to the feed air into the tower to recover the cold energy.
If the gaseous product requires a higher delivery pressure, it will be sent to the product compressor for pressurization and delivery to the downstream plant through the pipeline.
Liquid products (mainly liquid oxygen and liquid nitrogen) are preferentially pressurized by cryogenic liquid pumps. Compared with gas compression, liquid pumping has obvious advantages in energy consumption; the pressurized liquid can be directly stored in an adiabatic cryogenic storage tank or converted into gas by a vaporizer.
The waste nitrogen generated in the process is preferentially supplied to the molecular sieve of the pre-purification unit for regeneration. The excess waste gas meets the standard and is vented. Modern air separation units can flexibly adjust the output ratio of gas and liquid products to match customer production fluctuations.
The distillation column is very sensitive to the disturbance of working conditions, and the whole device must be operated stably and continuously for a long time. Relying on heat integration and efficient expansion refrigeration, cryogenic air separation can realize the economic production of large-scale industrial gas.
The complete set of modern cryogenic air separation (ASU) is divided into warm end equipment and cold end equipment. Each unit cooperates with each other and is a highly integrated system.
Pre-purification unit PPU/molecular sieve adsorber: two-bed or multi-bed temperature swing adsorption system. Remove residual water, carbon dioxide and hydrocarbons to prevent impurities from freezing and blocking in the cold box. Alternate adsorption and regeneration of the bed to ensure uninterrupted operation.
The cryogenic distillation process can stably produce ultra-high purity industrial gas. The purity of oxygen is 99.5, which can reach 99.6~99.8 after optimization design. Nitrogen can reach up to 99.999, oxygen impurity can be controlled at ppb level, and the purity of argon is higher than 99.9.
The cryogenic air separation device is suitable for all-weather continuous operation and has a huge capacity. The daily output of a single unit can reach hundreds to thousands of tons, and the gas flow can reach tens of thousands of standard cubic meters per hour.
When the oxygen demand is greater than 700 ~ 1000nm/h, or the nitrogen demand is greater than 2000 ~ 3000nm/h. Scale effect and efficient heat integration, so that the energy consumption per unit of product is better than other processes.
Cryogenic air separation can efficiently produce liquid oxygen LOX and liquid nitrogen LIN. Cryogenic liquids can be stored in insulated storage tanks, transported over long distances using tank trucks, and can also be used as a backup source for peak shaving.
Cryogenic pre-equipment investment (CAPEX) is higher, and the start-up time is several hours to one day. PSA, membrane separation start-up only takes a few minutes, but in a stable large demand scenario, the long-term cost of deep-cold devices is better.
The core advantage comes from the design of high-efficiency multi-stream heat exchanger and double tower thermal coupling. Liquid pumping replaces gas compression, while argon and liquid products generate additional sales revenue and dilute unit costs.
For steel mills, chemical plants, refineries, large medical gas bases such as long-term stable industrial gas supply projects. The total life cycle cost of ownership (TCO) will be significantly better than small and medium-sized non-cryogenic equipment.
| Criterion | Cryogenic Air Separation | PSA / VPSA | Membrane Separation |
| Operating Principle | Low-temperature fractional distillation | Selective adsorption under pressure | Selective permeation through polymer membranes |
| Typical O₂ Purity | ≥ 99.5% (up to 99.9%+) | 90-95% (higher possible but costly) | 30-45% (oxygen-enriched air only) |
| Typical N₂ Purity | 99.9% – 99.999%+ | 95% – 99.999% | 95% – 99.5% |
| Argon Recovery | Yes (high purity) | No | No |
| Liquid Products | Yes (LOX, LIN, LAR) | No | No |
| Capacity Range | Medium to very large (hundreds-thousands of tons/day) | Small to medium | Small to medium |
| Energy Consumption | Higher at small scale; competitive/better at large scale | Low to moderate | Lowest for moderate purity |
| Capital Cost (Capex) | High | Medium | Low to medium |
| Start-up / Response | Slow (hours) | Fast (minutes) | Very fast (minutes) |
| Footprint | Large | Compact | Most compact |
| Maintenance Complexity | High (compressors, turbines, cold box) | Moderate (valves, adsorbent beds) | Low (membrane modules replaceable) |
| Best Applications | Steel, chemicals, large medical, electronics, liquid supply, multi-product | On-site moderate-purity gas, hospitals, mid-size industry | Inerting, blanketing, simple enrichment, remote/small sites |
| Key Strength | Highest purity + large volume + liquids + multi-gas | Flexibility + moderate purity at lower cost | Simplicity + lowest cost for basic needs |
| Key Limitation | High capital, long start-up, complex | Limited purity (especially O₂) and no liquids | Lowest purity; no high-purity O₂ or argon |

In the operating cost of cryogenic air separation plant, power consumption accounts for the majority. Modern installations consume about 170-250 kWh per ton of oxygen produced. Among them, the main air compressor accounts for 65% ~ 75% of the total power consumption. The core factors affecting energy consumption are analyzed item by item below.
Ambient temperature and humidity, dust, CO₂ will increase the load on the compressor and purification system. The intake air with high temperature and high humidity and many impurities not only increases the power consumption, but also accelerates the loss of molecular sieve.
The higher the product purity, the higher the energy consumption. The higher the recovery rate of oxygen and argon, the better the utilization rate of feed air. Insufficient recovery rate will cause compressed air to vent and waste electricity. When the price of electricity fluctuates, the purity and recovery rate can be adjusted moderately to control the cost.
The production of liquid oxygen, liquid nitrogen and liquid argon requires additional refrigeration, which mainly depends on the turbine expander to obtain cold energy. The higher the proportion of liquid output, the higher the unit energy consumption; only gaseous products have the lowest energy consumption.
The heat integration of the main heat exchanger and the cold box is the core of air separation energy saving, and the temperature difference between the cold and hot ends is controlled at 1-3K. Large pipe resistance, cold box insulation failure, heat exchanger scaling, will increase the heat leakage, energy consumption increased by up to 15%.
The selection of cryogenic air separation plants requires a systematic assessment of technical requirements, site conditions, economics and manufacturer strength. System evaluation can ensure stable and reliable equipment, controllable operating costs, and realize long-term investment value.
The first step is to quantify gas demand. The average flow rate and peak flow rate of oxygen, nitrogen and argon are counted.
Determine the target purity, such as oxygen 99.5% or more than 99.6%, high purity nitrogen oxygen content ; 3ppm, high purity argon index. Confirm the gas supply pressure, continuous 24-hour operation capacity, load regulation range and standby gas supply scheme.
Air separation gas production site conditions will directly affect the equipment design and cost. The local ambient temperature, altitude, and air humidity need to be investigated, and the parameters will change the compressor power consumption and cooling load.
Evaluate the water quality and supply capacity of cooling water, and consider the air cooling scheme without water source scenario. At the same time, confirm the stability of power supply, the available area of the air separation plant, the original pipe network, the storage tank loading facilities and the downstream process interface.
The choice of air separation equipment can not only compare the purchase price of cryogenic equipment, to calculate the full cycle cost.
One-time capital investment including equipment, installation, civil engineering and commissioning. Operating costs are dominated by electricity (170-250kWh per ton of oxygen), plus maintenance consumables (molecular sieves, lubricants) and labor costs.
At the same time, the spare parts supply capacity, long-term reliability, equipment availability, and the total life cycle cost of 20 to 30 years are evaluated.
Priority is given to air separation plant manufacturers with full project cycle services: process package development, equipment manufacturing, on-site construction, start-up commissioning, long-term maintenance.
Fullcryo provide customized cryogenic air separation overall solution, with independent process technology and full equipment manufacturing capacity. The product covers small and medium-sized air separation to large-scale full-extraction air separation devices (oxygen, nitrogen and argon co-production), which can be customized according to customer capacity, purity, liquid-gas ratio and self-control requirements, and continuously optimize energy consumption and full life cycle costs.
A: The cryogenic air separation plant compresses the ambient air to remove water, carbon dioxide and hydrocarbon impurities. The purified air enters the high-efficiency heat exchanger to cool to cryogenic temperature and partially liquefies. The gas-liquid mixture is sent to the rectifying tower, and the separation is completed by the difference of boiling point of each component.
A: The whole ASU is in the cryogenic zone, about -170 ℃ to -196 ℃. The temperature at different positions varies with pressure and medium composition, and there is no uniform fixed temperature.
A: Utilizing the difference in volatility (boiling point). At atmospheric pressure, the boiling point of nitrogen is about -196 ℃, and that of oxygen is about -183 ℃. Continuous gas-liquid contact on the packing or tray in the tower, the more volatile nitrogen continuously enters the rising vapor; the less volatile oxygen remains in the liquid phase. The reflux liquid at the top of the tower and the rising gas phase at the bottom of the tower maintain a concentration gradient, the top of the tower produces high-purity nitrogen, and the bottom of the tower obtains high-purity liquid oxygen.
A: Yes. The liquid is extracted from the corresponding position of the rectification system and sent to the adiabatic cryogenic storage tank for storage to obtain liquid oxygen LOX and liquid nitrogen LIN.
A: Yes. The side gas phase is extracted from the argon enrichment zone in the middle of the low pressure rectification column and sent to the independent argon rectification column for multi-stage purification. Argon recovery and final purity depend on process configuration, column design, and product specifications.
A: Including air separation unit capacity, product purity, gaseous product delivery pressure, liquid-gas output ratio, compressor and expander efficiency, ambient temperature and humidity, heat exchanger heat integration level. Large air separation plant, producing 170-250 kWh per ton of oxygen.
A: The start-up time is affected by the scale of the device, the hot/cold state of the cold box, the process design and the automatic control system. Cold box completely at room temperature state of large equipment, hot state drive takes several hours to a day. If the cold box is kept at a low pressure, it will restart much faster.
The cryogenic air separation unit is an industry benchmark solution for large-scale, ultra-high purity oxygen, nitrogen and argon production. If you are planning a cryogenic air separation project, you need a process plan, energy consumption measurement and equipment quotation. Welcome to contact Fullcryo to obtain customized cryogenic air separation project plan.